Fire Resistant Roller Shutters - Large

MODEL: LBS FIREGUARD FM75
SKU: FM-75
IN STOCK
Insulated fire resistant steel roller shutter installation for Weald School cafeteria servery

PRODUCT DESCRIPTION

The LBS FireGuard FM75 is the go-to choice for enhanced fire protection across a range of settings—schools, serving hatches, receptions, warehouses, and food preparation areas. Certified to offer up to 4-hour fire resistance, this steel roller shutter complies with LPS 1056: Issue 5 Certification, setting the standard for fire doors, lift landing doors, and shutters.

Incorporating a gravity failsafe, a mandatory requirement for fire-rated doors and shutters, this model guarantees closure in the event of a fire, even when there's a loss of power, eliminating the need for a secondary power source.

Constructed with a solid steel, traditionally curved 3-inch lath and a chain-driven flange-mounted motor, the FireGuard FM75 is not just for emergencies; it's also versatile enough for daily security use over counters, serving hatches, and other openings.

For further information or to discuss your specific requirements, our team is available to offer expert advice and quotations. Technical specifications, drawings, and data sheets for this product are available upon request.

TECHNICAL DATA

Drawigns

Contact Us

PRODUCT SPECIFICATIONS

COMMON USE

Schools, Severy Hatches, Receptions, Warehouse, Food Prep Areas

DIMENSIONS

7000x7000mm with oversize assessments for up to 10,000x3500mm

FINISH

The standard finish consists of a self-finish galvanised steel curtain with primed guides, complete with mounting angles as needed. Alternatively, these shutters can be supplied with standard stock polyester powder coat finishes in a range of RAL colours.

OPERATION

These shutters are electrically operated, driven by a 240v 1-phase or 3-phase (depending on size) flange-mounted inline chain-driven motor.

APPLICATION

LBS FIREGUARD fire-resisting rolling shutters are engineered to deliver up to a 4-hour integrity rating and have been rigorously tested and approved to comply with BS EN 16034:2014, EN 13241, CE, and UKCA standards.

ARRANGEMENT

Our fire-resisting shutters feature a vertical roller curtain designed for face or reveal fixing.

Casing / FASCIA

A 3-sided galvanised steel coil casing and fascia are included where required.

BARREL

Utilising suitable mild steel tubing where necessary, finished with a rust-inhibitive primer. Mild steel plates are employed, also finished with a rust-inhibitive primer.

GUIDES

Vertical guide channels are employed, featuring a track retaining system that prevents the curtain from dislodging during exposure to heat or ventilation pressure.

ControlS

A fire control panel can be provided, offering timed delay functionality and audio-visual warnings. It is activated upon receiving a fire alarm signal (volt-free). Once activated, the unit initiates flashing lights and emits an audible warning, with the shutter closing after a predetermined delay of 10 to 240 seconds. Additionally, a repeated visual unit is available for placement on the opposite side of the opening to accommodate individuals with hearing difficulties.

CURTAIN

The curtain is composed of 75mm traditionally curved galvanised steel interlocking laths, equipped with steel endlocks and a pre-formed bottom rail.

PERFORMANCE

These shutters offer impressive fire resistance, which can withstand up to 4 hours of fire exposure, aligning perfectly with EN 16034:2014 harmonised technical specifications.

They are CE and UKCA marked, signifying their adherence to stringent European safety standards. Furthermore, these shutters have undergone testing and approval in accordance with BS EN 16034:2014, EN 13241.

They hold certification for both 'flexible' and 'rigid' structures, as outlined in the Extended Application Report BS EN 15269-10. Compliant with LPS 1056: Issue 5 Certification, which outlines requirements and tests for fire doors, lift landing doors, and shutters.

They are tested for closing and reset functionality, ensuring they remain in working order and are accompanied by a Certificate of Conformity.

DESIGN SERVICE
We offer a full design service, supply and installation of roller shutters and all of our products in any size.
24/7 URGENT REPAIRS
Get 24/7 emergency repairs to cover unexpected faults. LBS customer service is 365-day available.
MAINTENANCE
Ensure your premises are full protected with our planned preventative maintenance.
COMPLIANCE
Our maintenance packages can help premises comply with legal obligations and extend warranties.

WHAT OUR CUSTOMERS SAYS ABOUT US

RELATED PRODUCTS

Heavy duty roller grilles installation for a car park in Chelmsford

High Usage Car Park Roller Grilles

Honeycomb pattern roller grilles with anti-lifting devices and a noise reduction system. Tested for 450,000 operations
VIEW PRODUCT
car park grilles

Car Park Brickbond Grilles

Comprising of aluminium tubes & links, assorted on steel rods either in a brickbond or in-line pattern. Ideal for high use.
VIEW PRODUCT
roller shutters

Insulated / Glazed Sectional Overhead Doors

Providing warehouses, dock & level loading bays with security, thermal insulation and a sound reduction of up to 25dB.
VIEW PRODUCT

FIRE PROTECTION & SAFETY

Fire Protection is an integral part of a building's life safety system and, as such have a requirement to be maintained. LBS Group offers comprehensive maintenance packages that guarantee accordance with the relevant requirements and can economically extend normal warranty requirements.

ABOUT LBS GROUP

LBS Group is a Fire Protection specialist manufacturer and has been on the market for more than three decades. Over this long period, we’ve managed to maintain our stellar reputation and the excellent relationship that we have with numerous industrial and commercial clients

MORE PRODUCTS IN OUR RANGE

Active fire and smoke barrier deployed

Fire and Smoke Curtains

Active fire barriers are a lightweight, discrete and, due to their gravity fail to safe functioning, reliable method of providing fire and smoke rated compartments whilst leaving areas open and unencumbered.
VIEW PRODUCT
Insulated fire resistant steel roller shutter installation for a kiosk in Romford Leisure Centre

Fire Resistant Roller Shutters – TM75

Solid steel Fire Resistant Roller Shutters perfect for smaller openings requiring a smaller coil casing and tubular motor due to headroom requirements. Designed and certified to provide a fire resistance of integrity (e) for up to 4 hours
VIEW PRODUCT
Fire Rated Fire Exit Door

Fire Rated and Fire Exit Doors

LBS Fire exit doors are tested to provide up to 240 minutes fire resistance. A complete range of locking, glazing, infill panels and louvre options available
VIEW PRODUCT

ACCREDITATIONS

LBS industry accreditations
pencilcoglicensewarning